Pharma and health

AI in clinical trials: what ICH, the FDA, the EMA and Health Canada expect

An AI tool that codes adverse events or triages queries falls within good clinical practice. No regulator prohibits it; all of them want proof that it does what you expect of it. Here is what the texts say, and what to document before the audit.

By Kantara Fofana

Published 10 min read

In short

  • No regulator prohibits AI in a clinical trial; ICH E6(R3), the good clinical practice standard adopted on January 6, 2025, does not even name it: an AI tool is a computerized system like any other, to be validated based on risk.
  • Health Canada has applied ICH E6(R3) since April 1, 2026 and, since October 27, 2026, has recommended that sponsors validate the intended use of AI and monitor its performance in trials with decentralized elements.
  • In a January 2025 draft that is still not final, the FDA proposes establishing a model’s credibility in seven steps, based on its context of use, its influence and the consequence of an error.
  • The EMA expects a frozen model for the analysis of a pivotal trial.
  • Before an audit, you need to be able to show the inventory of AI tools, their intended use, the risk, the validation, the audit trail, change management and human review.

The question the inspector will ask

A good clinical practice inspection at a sponsor. The inspector asks how the trial’s adverse events were coded. The answer: an AI tool suggests the medical dictionary term, and a coder accepts or corrects it. Then come the real questions: which model version suggested what; validated how, on which data; who accepted each term; and what has changed since the first participant.

None of these questions is specific to AI: good clinical practice asks them of every computerized system. AI makes them harder, because a model can be wrong in plausible ways, change with an update or degrade on new data. Yet it is already in the files: the U.S. Food and Drug Administration (FDA) received more than 500 submissions with AI components from 2016 to 2023. For sponsors, contract research organizations (CROs) and their vendors, the expectations are now in writing, and they converge.

ICH E6(R3): an AI tool is a computerized system like any other

The third revision of good clinical practice, E6(R3) from the International Council for Harmonisation (ICH), is meant to be media neutral: it names neither artificial intelligence nor machine learning, and neither does its consolidated version of June 16, 2026, which adds an annex on decentralized and pragmatic trials. An AI tool is therefore a computerized system, subject to the same requirements, notably those on data governance (section 4), in proportion to the risks to participants and to the reliability of results (principle 7). Its principles and Annex 1 have been in effect in the European Union since July 23, 2025, and the FDA issued it as final guidance in September 2025.

What ICH E6(R3) expects of a computerized system, and so of an AI tool
ExpectationSectionFor an AI tool
Fit for purpose, validated based on riskPrinciple 9.3; 4.3.4Validation starts from the intended use and the possible effect on participants and on results.
Revalidate what changes4.3.4(c)A new model version is a change, to be validated based on risk.
Validate automated checks and calculations4.3.4(e)A trial calculation belongs in a validated formula, not in a language model.
An audit trail that is never disabled4.2.2; 4.2.4Who did what, when and, where applicable, why; every correction attributed to a person or a system.
Limited, attributable access4.3.8Permissions based on each person’s duties, reviewed periodically.
Oversee service providersPrinciple 10; 3.6; 3.9The sponsor can transfer activities, not its responsibility: it selects, sets out agreements and oversees, subcontractors included.

Health Canada: the Regulations bind, the guidance explains

Under Canadian law, it is the Food and Drug Regulations that bind; ICH E6(R3) helps interpret them, and the Regulations prevail where they go further. Part C, Division 5 requires that “systems and procedures that assure the quality of every aspect of the clinical trial are implemented” (s. C.05.010(c)). Trial information is recorded, handled and stored in a way that allows its complete and accurate reporting, its interpretation and its verification (s. C.05.012(1)), and records are kept for 15 years (s. C.05.012(4)). Division 5 is due to be replaced by Clinical Trials Regulations, proposed on December 20, 2025; Health Canada expects to publish the final version in spring 2027, followed by a one-year transition.

Health Canada adopted ICH E6(R3) on April 1, 2026. Under its GUI-0100 guidance, evidence of validation is kept as long as the records, available to inspectors; records processed in the cloud follow the same requirements as a company’s own; and observations on system validation are usually cited under paragraph C.05.010(c).

Note

Health Canada names AI

Under its October 27, 2026 guidance for clinical trials with decentralized elements, where algorithmic tools or AI are used, sponsors should validate their intended use and monitor their performance throughout the trial, taking into account bias, version control, change management and the potential for algorithm drift (performance that degrades).

FDA: a model’s credibility in seven steps, still a draft

On January 6, 2025, the FDA issued its first guidance on AI in drug development. It is a draft: as of October 29, 2026, its page still presents it that way, and its recommendations bind no one. It covers AI that produces data to support a regulatory decision on safety, effectiveness or quality, and excludes drug discovery and efficiency gains, such as drafting a submission, that have no effect on patient safety, drug quality or the reliability of results.

  1. Define the question of interest

    The question, decision or concern the model addresses.

  2. Define the context of use

    The model’s role and scope, and the other evidence used alongside it.

  3. Assess the model risk

    Its influence, the weight of its evidence among the rest, and the consequence of a wrong decision.

  4. Plan the credibility assessment

    Describe the model, its data, its training and its testing on independent data.

  5. Execute the plan

    Ideally after discussing it with the FDA.

  6. Document results and deviations

    In a report included in a submission, or provided on request, for example at inspection.

  7. Decide whether the model is adequate

    If not: lower its influence, strengthen the assessment, add controls, change the approach or revise the context.

In the draft’s examples, a model that alone decides which participants go home after a dose that can cause a life-threatening reaction carries high risk; a vial fill check backed by an independent measurement on a sample from each batch carries medium risk. With a human in the loop, you assess the human-AI team, not the model alone; a model that can change is monitored throughout its life cycle.

This draft comes on top of the rules in force: for closed systems, Part 11 of Title 21 of the Code of Federal Regulations (CFR) requires system validation, access limited to authorized individuals, training for those who develop, maintain or use the systems, and secure, time-stamped audit trails kept as long as the records (§ 11.10). The FDA’s final October 2024 guidance on electronic systems in clinical investigations recommends risk-based validation and reminds sponsors that they must be able to show, at inspection, the validation performed by their vendor.

EMA: a frozen model for the pivotal trial

The European Medicines Agency (EMA) reflection paper, adopted on September 9, 2024, is not a rule, but it signals what assessors and inspectors will expect. AI used in a trial should follow ICH E6. Where regulatory impact or patient risk is high, and the method has not been qualified by the EMA for that context, the model architecture, its development and testing logs, its training data and its data processing pipeline would likely be treated as trial data, which may be requested during assessment or inspection.

  • A model that analyzes or interprets trial data is part of the statistical analysis; in late-stage development, it is frozen, or EMA-qualified, and described in the statistical analysis plan.
  • In a pivotal trial, the one a marketing application rests on, incremental learning (a model that keeps learning as it is used) is not accepted, and any change to the model during the trial requires regulatory interaction.
  • After marketing authorization, in pharmacovigilance, the model may keep learning, but the marketing authorization holder must validate, monitor and document its performance.

Its 2023 guideline on computerized systems in clinical trials defines AI broadly, from if-then rules to deep learning, and brings within its scope AI used for recruitment, eligibility, coding, queries and event adjudication: the expectations that apply to every system apply to it, pending a possible AI-specific annex.

From protocol to pharmacovigilance: risk, use by use

The same tool changes risk with its context of use: a coder who reviews every term lowers the model’s influence; a triage nobody reviews raises it. This table offers one reading of the texts, not an official grid.

AI uses in a trial: likely risk and evidence to gather (recommendation)
UseWhat the model influencesLikely riskWhat you must be able to show
Protocol draftingA text that is reviewed and approvedLow, if the review is realTraced approval; no participant data in the tool
Site selectionA ranking the team arbitratesLow to mediumThe criteria used; the sponsor’s final choice (3.7.1)
RecruitmentWho is put forward as a candidateMedium; high if the tool screens people out on its ownMissed candidates; the qualified investigator’s medical decision (C.05.010(f))
Data cleaning and queriesQueries raised and corrections suggestedMediumEvery correction attributed and justified by the source (4.2.4)
Medical codingThe term chosen for an event or a medicationMedium to highMeasured agreement with coders; model and dictionary versions
Pharmacovigilance case intakeA case’s triage and seriousnessHighNo lost cases: a serious unexpected adverse drug reaction has 7 days from awareness to reach the Minister if fatal or life-threatening, 15 otherwise (C.05.014)
Risk-based monitoringSites flagged for a targeted visitMediumDocumented flagging logic, reviewed by qualified people (3.11.4.2)
Trial master file reviewEssential records flagged as missingLow to mediumA sample reviewed by a person; nothing filed or changed by the tool alone
Key point

ALCOA+: the test for every piece of data AI touches

Guide PI 041-1 (2021) from the PIC/S pharmaceutical inspectors, written for manufacturing and distribution, sums up data integrity as ALCOA: attributable, legible, contemporaneous, original and accurate; the “+” adds complete, consistent, enduring and available. For trials, the EMA adds traceable (ALCOA++) and wants coding controlled. In practice: data suggested by a model stays attributable to the system and its version, then to the person who accepted it.

Before the audit or inspection: twelve pieces of evidence

  • Inventory: the systems that contain AI, including features added by an update and tools used without authorization, each with its owner (3.16.1(x)(i)).
  • Intended use: the question of interest and the context of use of each tool, in writing.
  • Risk: the model’s influence and the consequence of an error, assessed and dated.
  • Validation: tests on representative data, independent of the training data, with acceptance criteria set in advance.
  • Human review: performance measured with the review as actually done, and a record of each review.
  • Audit trail: every model suggestion and every human decision, with author, date, time and model version.
  • Access: who can use, configure or retrain the tool, with permissions reviewed (4.3.8).
  • Changes: every new version of the model, its data or its instructions assessed as a change; a frozen model for any confirmatory analysis.
  • Vendors: their qualification, and an agreement providing for audit rights, notice of model changes and oversight of subcontractors (3.6).
  • Training: users trained on the tool and its limits (4.3.2).
  • Procedures: when the tool is used, who reviews its outputs, how to suspend it if it drifts.
  • Data and privacy: data provenance and protection of participants’ personal information (3.16.1(t)); in Quebec, see Law 25 and AI.

Vendors to sponsors and CROs: what you will be asked

If you supply sponsors or CROs with technology used in their trials, you are a service provider within the meaning of ICH E6(R3). The sponsor, which keeps final responsibility, assesses a provider before selecting it, has access to its procedures and metrics, and oversees its subcontractors (3.6.6 to 3.6.9). Expect to be asked for:

  • what in your tool is really AI;
  • the validated context of use, and the data behind that validation;
  • the model version used on each date, your change procedure and an exportable audit trail;
  • where participant data is processed, and whether it is used to train your models.

The EMA is explicit in its notice to sponsors revised on October 29, 2026: a system whose validation cannot be shown to inspectors must not be used in a trial, and systems from a vendor that refuses access to its specifications, to audits or to inspectors must not be used. To spot software that calls itself “AI” without being it, see AI washing: questions to ask the vendor. Qualification exists too: in March 2025, the EMA qualified a first AI tool, which reads liver biopsies in steatohepatitis (MASH) trials.

Frequently asked questions

Does an AI tool used in a clinical trial need to be validated?
Yes, as soon as it plays a part in a trial process: ICH E6(R3) recommends validating every computerized system based on a risk assessment. The effort is proportionate: a drafting aid reviewed by a person needs less than a model that codes adverse events.
What does “validating” an AI model mean in a clinical trial?
Not the same thing as in data science, where “validation data” is used to tune the model. In good clinical practice, validating means demonstrating and documenting that the system reliably does what is expected of it, for its intended use. The FDA and the EMA both flag this confusion.
Is the FDA’s guidance on AI in drug development final?
No. As of October 29, 2026, the January 2025 guidance is still a draft, whose recommendations bind no one. Part 11 of Title 21 of the CFR nonetheless applies to the electronic records the tool produces where those records are required by, or submitted to, the FDA.
Can an employee use a consumer AI assistant for a trial document?
Not with participant information or trial data: the tool is not validated, not covered by an agreement and has no audit trail you control. For drafting help that involves no confidential data, require review and approval by a responsible person.

Sources

Every fact in this article links to its official source, consulted on October 29, 2026.

  1. International Council for Harmonisation (ICH)Guideline for Good Clinical Practice E6(R3), version adopted on January 6, 2025 (opens in a new tab)
  2. International Council for Harmonisation (ICH)Guideline for Good Clinical Practice E6(R3), consolidated version, June 16, 2026 (opens in a new tab)
  3. Health CanadaGuidance Document: Part C, Division 5 of the Food and Drug Regulations “Drugs for Clinical Trials Involving Human Subjects” (GUI-0100): Overview (opens in a new tab)
  4. Health CanadaGUI-0100: Labelling and records (opens in a new tab)
  5. Health CanadaGuidance for clinical trials with decentralized elements: Designing the trial (October 27, 2026) (opens in a new tab)
  6. Health CanadaModernizing the clinical trials framework: What we heard (opens in a new tab)
  7. Canada GazettePart I, Vol. 159, No. 51, December 20, 2025: Clinical Trials Regulations (proposed) (opens in a new tab)
  8. Justice Laws WebsiteFood and Drug Regulations (C.R.C., c. 870), s. C.05.010 (opens in a new tab)
  9. Justice Laws WebsiteFood and Drug Regulations (C.R.C., c. 870), s. C.05.012 (opens in a new tab)
  10. Justice Laws WebsiteFood and Drug Regulations (C.R.C., c. 870), s. C.05.014 (opens in a new tab)
  11. U.S. Food and Drug AdministrationConsiderations for the Use of Artificial Intelligence to Support Regulatory Decision-Making for Drug and Biological Products, draft guidance, January 2025 (opens in a new tab)
  12. U.S. Food and Drug AdministrationFDA Proposes Framework to Advance Credibility of AI Models Used for Drug and Biological Product Submissions, January 6, 2025 (opens in a new tab)
  13. U.S. Food and Drug AdministrationE6(R3) Good Clinical Practice (GCP), final guidance, September 2025 (opens in a new tab)
  14. U.S. Food and Drug AdministrationArtificial Intelligence for Drug Development, CDER (opens in a new tab)
  15. U.S. Food and Drug AdministrationElectronic Systems, Electronic Records, and Electronic Signatures in Clinical Investigations: Questions and Answers, final guidance, October 2024 (opens in a new tab)
  16. U.S. Government Publishing Office (govinfo)21 CFR Part 11, Electronic Records; Electronic Signatures, April 1, 2025 edition (opens in a new tab)
  17. European Medicines Agency (EMA)Reflection paper on the use of Artificial Intelligence (AI) in the medicinal product lifecycle, September 9, 2024 (opens in a new tab)
  18. European Medicines Agency (EMA)Guideline on computerised systems and electronic data in clinical trials, 2023 (opens in a new tab)
  19. European Medicines Agency (EMA)ICH E6 Good clinical practice, Scientific guideline (opens in a new tab)
  20. European Medicines Agency (EMA)Notice to sponsors on validation and qualification of computerised systems used in clinical trials, revised October 29, 2026 (opens in a new tab)
  21. European Medicines Agency (EMA)EMA qualifies first artificial intelligence tool to diagnose inflammatory liver disease (MASH) in biopsy samples, March 20, 2025 (opens in a new tab)
  22. PIC/SPI 041-1, Good Practices for Data Management and Integrity in Regulated GMP/GDP Environments, July 1, 2021 (opens in a new tab)

This article provides general information. It is not legal, tax or accounting advice for your situation.

All articles

Keep reading

Your case deserves thirty minutes.

A free consultation to understand your context and tell you, frankly, whether we are the right choice, and where to start.

Book a call